page 35
ITEM REQ’D PART NO. AQUALUNG
PART NO.
DESCRIPTION
PRS6
1 1 PRS6-1 820040 O-RING
2 1 PRS6-3 106058 STEM (Cannot be purchased separately.)
3 1 PRS6-2 820039 O-RING
4 1 PRS6-4 108657 HANDWHEEL (Cannot be purchased separately.)
5 1 PRS6-5 054159 1/4”NPT FITTING (Cannot be purchased separately.)
6 1 347-1 103248 CGA 347 TO 1/4” FNPT BRASS
PRS6 OVERHAUL
To disassemble, hold 1/4” NPT tting (5) using 11/16” socket. Using a 6mm Allen 1.
wrench, unscrew stem (2) with a counter-clockwise motion.
Remove O-rings from stem, using O-ring pick. Discard. 2.
The 820039 O-ring (3) on the PRS/MRS DIN connector must have a light coat of non-3.
toxic lubricant (Christo-Lube) applied prior to being installed on the assembly. NOTE:
Do not apply any lubricant to the 820040 O-ring (1).
Install lubricated O-ring (3) over the threads of the stem (2) taking care to not damage the 4.
O-ring.
Install O-ring (1) all the way back into the O-ring groove of stem (2).5.
Place the handwheel (4) over the 1/4” NPT tting (5) with the threads pointed upward.6.
Thread stem (2) into 1/4” NPT tting (5) using a 6mm Allen wrench. Use 11/16” socket 7.
to hold 1/4” NPT tting.
Torque stem (2) to 1/4” NPT tting (5) -- 40.0 +/- 5.0 inch pounds.8.