Aqua Lung SEA MK Anleitung zur Fehlerbehebung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
23
SYMPTOM POSSIBLE CAUSE TREATMENT
System will not remain depressurized
after valve is shut and second stage is
purged.
1. The valve seat (20) is worn or damaged. 1. Replace valve seat
2. The valve seating surface is damaged. 2. Replace body (36)
High or Unstable IP “Creep”
1. The valve seat (20) is worn or damaged. 1. Replace valve seat
2. The valve seating surface is damaged. 2. Replace body (36)
3. The main spring (35) is defective 3. Replace main spring
4. The HP seat (34) is worn or damaged. 4. Replace HP seat
5. The HP crown sealing surface is
damaged.
5. Replace body (36)
Low IP
1. Main spring (35) is weakened or
damaged.
1. Replace spring
External Air Leak
1.The piston head o-ring (31) or shaft o-ring
(33) is worn or damaged.
1. Replace o-ring (s)
2. The o-ring grooves on the piston (32)
are damaged.
2. Replace piston and o-rings
3. The piston head o-ring sealing surface in
the piston cap (30) is damaged.
3. Replace piston cap
4. The piston shaft o-ring sealing surface in
the body is damaged.
4.Replace body
Table 1: Troubleshooting Guide
First Stage/Valve Assembly
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare