2.2 Features
Calypso Titan / Mikron Kronos / Legend
First stage Piston regulator Diaphragm regulator Diaphragm regulator
technolgy
Maximum working Yoke : 232 bar Yoke : 232 bar Yoke : 232 bar
pressure USA : 3300 PSI USA : 3300 PSI USA : 3300 PSI
DIN : N/A DIN : 300 bar DIN : 300 bar
Number of ports 1 HP 7/16, 4 MP 3/8 1HP 7/16, 4 MP 3/8 2 HP 7/16 , 4 MP 3/8
Hose length 730 MM 730 MM 730 MM
2.3 VANE ADJUSTMENT SWITCH (VAS)
Calypso /Titan Kronos Titan LX/Legend Legend LX
Most of our second stages are fitted with a Vane Adjustment Switch (VAS).
The VAS can be found in one of two different locations depending upon which
model you have. It can be located on the side opposite the hose connection OR
it can be found on top in front of the mouthpiece. It helps to maintain a high
flow of air once you have started to take a breath.
When the VAS is set to the “MAX” (or “+”) position, the regulator will provide
maximum venturi assistance.
When the VAS is set to the “MIN” (or “-”) position, breathing resistance is
increased.
You should put it on the “MIN” (or “-”) position whenever the regulator second
stage is out of your mouth.
You may put it on the “MAX” (or “+”) position whenever the mouthpiece is in
your mouth.